LEADER 00000cam a2200637Ia 4500 001 ocn228835119 003 OCoLC 005 20160527041420.4 006 m o d 007 cr gn||||||||| 008 080527s2001 enka ob 101 0 eng 020 9781847551696|q(electronic book) 020 1847551696|q(electronic book) 024 7 10.1039/9781847551696|2doi 035 (OCoLC)228835119 037 10.1039/9781847551696|bRoyal Society of Chemistry|nhttp:// www.rsc.org/spr 040 OKU|beng|epn|cOKU|dOKU|dUKRSC|dCOO|dU5D|dCUS|dOCLCQ|dN$T |dE7B|dOCLCF|dOCLCQ|dOCLCO|dYDXCP|dOCLCQ|dOCLCO|dOCL |dOCLCO|dOCLCQ 049 RIDW 050 4 QD96.M3|bP55 2001eb 072 7 SCI|x013010|2bisacsh 082 04 543.0873|221 090 QD96.M3|bP55 2001eb 111 2 International Conference on Plasma Source Mass Spectrometry|0https://id.loc.gov/authorities/names/ nr93035475|n(7th :|d2000 :|cUniversity of Durham) 245 10 Plasma source mass spectrometry :|bthe new millennium / |cedited by Grenville Holland, Scott D. Tanner. 264 1 Cambridge :|bRoyal Society of Chemistry,|c[2001] 264 4 |c©2001 300 1 online resource (x, 427 pages) :|billustrations. 336 text|btxt|2rdacontent 337 computer|bc|2rdamedia 338 online resource|bcr|2rdacarrier 340 |gmonochrome|2rdacc 347 text file|2rdaft 490 1 Special publication ;|vno. 267 504 Includes bibliographical references and index. 505 0 Sample introduction, plasma-sample interactions, ion transport and ion-molecule reactions : fundamental understanding and practical improvements in ICP-MS -- Microwave digestion of oils for analysis of platinum group and rare earth elements by ICP-MS -- USN-ICPMS : a poor man's high resolution -- The characteristics of an off- line matrix removal/pre-concentration system which uses controlled pore glass iminodiacetate as a reagent for inductively coupled plasma mass spectrometry -- Moving to the next level : sample introduction and plasma interface design for improved performance in ICP-MS -- QMF operation with quadrupole excitation -- All the ions all the time : dream or reality? -- Evaluation of inductively coupled plasma-ion trap mass spectrometry -- Reaction chemistry and collisional processes in multipole devices -- Ion- molecule reactions in plasma source mas spectrometry -- Ion-molecule chemistry solutions to the ICP-MS analytical challenges -- A reaction mechanism for solving the oxide problem in ICP-MS analysis for the noble metals -- Application and quality of ICP-MS analysis -- Trace elements in honey samples by means of ETV-ICP-MS -- Determination of trace elements in ice core samples by laser ablation inductively coupled plasma mass spectrometry -- Rare earth element concentrations for the Mobile-Alabama River systems -- Application of ICP-MS to a trace elements mass balance study in a power plant -- Determination of mercury, arsenic, selenium and antimony in potable water by ICP-MS -- Determination of metals in sewage and industrial waste waters by ICP-MS in a single runs -- The performance of commercial mono-elemental solutions for high accuracy mass spectrometry -- ICP-MS applied to isotope abundance ratio measurements : performance study and development of a method for combining uncertainty contributions from measurement correction factors -- Comparison of MC-ICP-MS with quadrupole ICP-MS for the certification of the amount, content and isotopic composition of enriched 206Pb and 203Ti materials using isotope dilution -- Which way for Os? A comparison of plasma-source versus negative thermal ionisation mass spectrometry for Os isotope measurement -- Matrix-induced isotopic mass fractionation in the ICP-MS - - Simultaneous acquisition of isotope compositions and parent/daughter ratios by non-isotope dilution-mode plasma ionisation muti-colector mass spectrometry (PIMMS) -- Combined Pb, Sr- and O-isotope analysis of human dental tissue for the reconstruction of archaeological residential mobility -- Isotope dilution analysis for trace metal speciation -- Prediction of inorganic aqueous speciation : a useful tool for ICP-MS and IC-ICP-MS analysts -- Investigations into biovolatilisation of metal(loids) in the environment by using GC-ICP-MS analysis -- Time-of-flight inductively coupled plasma mass spectrometry for ultratrace speciation analysis of rganometallic compounds -- An appetite for arsenic : the seaweed eating sheep from Orkney -- Hyphenated IC-ICP-MS for the determination of arsenic speciation in acid mine drainage -- Selenium speciation in human urine -- Sensitive detection of platinum-bound DNA using ICP-MS and comparison to graphite furnace atomie absorption spectroscopy (GFAAS). 520 This product is not available separately, it is only sold as part of a set. There are 750 products in the set and these are all sold as one entity.|bThe understanding of the principles of ICP-MS and its application as an analytical technique is continually evolving and this book provides a unique snapshot of the current state-of-the- art. Plasma Source Mass Spectrometry: The New Millennium covers a diverse range of topics including the fate of the sample as it passes through the sample introduction system, chemical resolution using reaction and collision cells, various methods of mass analysis, approaches to account for spectral interferences, hyphenation methods to enable speciation, and the results of analyses ranging from natural waters and archaeological isotope ratios to organometallic speciation in biological materials. Describing explicitly the analytical methods that deal with current analytical challenges, and offering a current perspective on elemental analysis by plasma source mass spectrometry that is not to be found elsewhere, this book will be welcomed by both academics and industrialists as containing the most up-to-date information available on this burgeoning topic. 588 0 Online resource; title from title screen (viewed on July 30, 2008). 590 eBooks on EBSCOhost|bEBSCO eBook Subscription Academic Collection - North America 650 0 Plasma spectroscopy|0https://id.loc.gov/authorities/ subjects/sh85103083|vCongresses.|0https://id.loc.gov/ authorities/subjects/sh99001533 650 0 Mass spectrometry|vCongresses.|0https://id.loc.gov/ authorities/subjects/sh2008107511 650 7 Plasma spectroscopy.|2fast|0https://id.worldcat.org/fast/ 1066357 650 7 Mass spectrometry.|2fast|0https://id.worldcat.org/fast/ 1011435 655 4 Electronic books. 655 7 Conference papers and proceedings.|2fast|0https:// id.worldcat.org/fast/1423772 655 7 Conference papers and proceedings.|2lcgft|0https:// id.loc.gov/authorities/genreForms/gf2014026068 700 1 Holland, Grenville.|0https://id.loc.gov/authorities/names/ nr92021705 700 1 Tanner, Scott D.|0https://id.loc.gov/authorities/names/ nb97044200 776 08 |iPrint version:|aInternational Conference on Plasma Source Mass Spectrometry (7th : 2000 : University of Durham).|tPlasma source mass spectrometry.|dCambridge : Royal Society of Chemistry, 2001|z0854048952|w(DLC) 2005282225|w(OCoLC)46984206 830 0 Special publication (Royal Society of Chemistry (Great Britain)) ;|0https://id.loc.gov/authorities/names/ n42023070|vno. 267. 856 40 |uhttps://rider.idm.oclc.org/login?url=http:// search.ebscohost.com/login.aspx?direct=true&scope=site& db=nlebk&AN=496209|zOnline eBook. Access restricted to current Rider University students, faculty, and staff. 856 42 |3Instructions for reading/downloading this eBook|uhttp:// guides.rider.edu/ebooks/ebsco 901 MARCIVE 20231220 948 |d201606016|cEBSCO|tebscoebooksacademic|lridw 994 92|bRID